Web[Comment] Re: What is the Ith & Ir at MCCB stand for? 05/03/2010 8:46 AM thanks. this an old model MCCB from ABB. SACE SN1250 model. Installed last 1986 by the German Contractors here in KSA. All I want to know is if could still use this MCCB. But i think the best solution now is to buy a new MCCB. Rgards to all. Reply WebOct 23, 2015 · Rated Frame Current (Inm) is the maximum current value for which the MCCB is designed, and it also determines the physical dimensions of the device. The rated frame current defines the upper...
i.Teller - Fiserv
WebLong Pickup (Ir) value (multiplied by the ampere rating (In) of MCCB) sets the maximum current level which the circuit breaker will carry continuously. If MCB is 1000A Rating but … WebMCCB - EasyPact EZC,EZC400H4400N,400A,50kA,4Pole MCCB In stock SKU EZC400H4400N ₹ 36,780 ₹ 21,332 42% ( Prices are all exclusive of taxes ) Be the first to review this product Qty Product Description Country of Origin: China Technical Specifications No sellers found for this product. east cobb health park urgent care
Setting the Long-Time Overcurrent Protection (L or ANSI 49RMS/51)
Continuous Amps (Ir) varies the level of current the circuit breaker will carry without tripping. Ir is a percentage of the circuit breaker’s nominal rating (In). Continuous amps can be adjusted from 20 to 100 percentof the circuit breaker’s nominal rating. Go back to CB tripping settings ↑ See more Long-time delay causes the breaker to wait a certain amount of time to allow temporary inrush currents, such as those encountered when … See more Short-time pickup is used for selective tripping.The short-time pickup function determines the amount of current the breaker will carry for a short period of time, allowing downstream protective devices to clear short … See more Instantaneous pickup is used to trip the circuit breaker with no intentional delayat any current between 2 and 40 times the breaker’s continuous ampere setting (Ir). In this … See more Short-time delay, used in conjunction with short-time pickup, controls the time involved in postponing a short-time pickup trip. This allows better coordination with downstream … See more WebThe long-time protection tripping range is 1.05–1.20 Ir according to standard IEC/EN 60947-2. The default Ir pickup setting value is the maximum dial position In. The following table shows the Ir pickup value preset on the dial: The accuracy range is + 5%/+ 20%. Use the keypad to fine-tune the setting, in increments of 1 A: o The setting ... WeboThe long-time protection pickup Ir is set using a multi-position dial. The maximum setting value (maximum setting on adjustment dial) equals the trip unit rating value In. The following table shows the values of the pickup Ir (in amperes) for long-time protection that are displayed directly on the dial with respect to every trip unit rating. east cobb hardware